TECHNICAL SERVICE MANUAL
HEAVY-DUTY STEEL EXTERNAL BRACKET MOUNTED PUMPS
SERIES 123 AND 4123
SIZES LS, Q, QS, M
SECTION TSM 151.2
PAGE 1 OF 14
ISSUE B
CONTENTS
Introduction
Special Information
Maintenance
Packed Pumps
Mechanical Seal Pumps
Standard Rubber Bellows Type
(Sizes LS, Q, QS & M)
Optional Teflon Seal
Thrust Bearing Adjustment
Installation of Carbon Graphite Bushings
Pressure Relief Valve Instructions
INTRODUCTION
The illustrations in this manual are for identification purposes
only and cannot be used for ordering parts. Obtain a parts
list from the factory or a Viking Representative. Always give
complete name of part, part number and material with model
number and serial number of pump when ordering repai
r
parts. The unmounted pump or pump unit model numbe
r
and serial number are on the nameplate.
In the Viking model number system, basic size letters are
combined with series number (123 and 4123) indicating both
unmounted or mounted pump unit.
UNMOUNTED PUMP UNITS
PACKED
LS123
Q123
QS123
M123
MECH. SEAL
LS4123
Q4123
QS4123
M4123
Units are designated by the un-
mounted pump model numbers
followed by a letter(s)
indicating drive style.
V = V-Belt
D = Direct Connected
R = Viking Speed Reducer
P = Commercial Speed Reducer
This manual deals only with Series 123 and 4123 heavy-
duty Steel External Bracket Mounted Pumps. Refer to
Figures 1 through 14 for general configuration and
nomenclature used in this manual. Pump specifications and
recommendations are listed in Catalog Section 151, Series
123 and 4123 Heavy-Duty Steel External Bracket Mounted
Pumps.
FIGURE 1
SIZE LS
FIGURE 2
SIZES Q, QS AND M
VIKING PUMP INC.
A Unit of IDEX Corporation •
1
2
2
3
7
11
12
12
13
Vedere la pagina 0
1 2 3 4 5 6 ... 13 14

Sommario

Pagina 1 - TECHNICAL SERVICE MANUAL

TECHNICAL SERVICE MANUAL HEAVY-DUTY STEEL EXTERNAL BRACKET MOUNTED PUMPS SERIES 123 AND 4123 SIZES LS, Q, QS, M SECTION TSM 151.2 PAGE 1 OF 14 I

Pagina 2 - MAINTENANCE

6. Sealing faces on mechanical seals should not be touched with anything but fingers or a clean cloth. A tapered sleeve is available, at extra cos

Pagina 3 - PACKED PUMPS

SECTION TSM 151.2ISSUE B PAGE 11 OF 14 DANGER BEFORE STARTING PUMP, BE SURE ALL DRIVEEQUIPMENT GUARDS ARE IN PLACE. FAILURE TO PROPERLY MOUNT

Pagina 4

SECTION TSM 151.2 ISSUE B PAGE 12 OF 14 THRUST BEARING ADJUSTMENT Refer to FIGURE 12. 1. Loosen two setscrews over each outer and inner end ca

Pagina 5

PRESSURE RELIEF VALVE INSTRUCTIONS FIGURE 13 SIZE LS LIST OF PARTS 1. Valve Cap 6. Valve

Pagina 6 - ISSUE B PAGE 6 OF 14

DANGER BEFORE STARTING PUMP, BE SURE ALL DRIVE EQUIPMENT GUARDS ARE IN PLACE. FAILURE TO PROPERLY MOUNT GUARDS MAY RESULT IN SERIOUS

Pagina 7

ROTATION: Viking pumps operate equally well in a clockwise or counterclockwise rotation. Shaft rotation determines which port is suction and which

Pagina 8 - DISASSEMBLY

ITEM NAME OF PART ITEM NAME OF PART ITEM NAME OF PART 1 Locknut 14 Packing Retainer Washer 27 Idler Bushing 2 Lockwasher 15 Bracket Bushing 28

Pagina 9

DANGER BEFORE OPENING ANY VIKING PUMP LIQUID CHAMBER (PUMPING CHAMBER, RESERVOIR, RELIEF VALVE ADJUSTING CAP FITTING, ETC.) BE SURE: 1. THAT AN

Pagina 10

6. Carefully remove rotor and shaft to avoid damaging bracket bushing. 7. Remove packing gland from side of bracket. 8. Loosen four setscrews o

Pagina 11 - ASSEMBLY

SECTION TSM 151.2ISSUE B PAGE 6 OF 146. Using a 0.15-inch head gasket, install head and idler assembly on pump. Pump head and casing were marke

Pagina 12 - GRAPHITE BUSHINGS

ITEM NAME OF PART ITEM NAME OF PART ITEM NAME OF PART 1 Locknut 14 Mechanical Seal 27 Rotor and Shaft 2 Lockwasher 15 Set Collar 28 Idler and

Pagina 13 - DISASSEMBL

PAGE 8 OF 14ISSUE B SECTION TSM 151.2 DANGER BEFORE OPENING ANY VIKING PUMP LIQUID CHAMBER (PUMPING CHAMBER, RESERVOIR, RELIEF VALVE ADJUSTING CA

Pagina 14

SECTION TSM 151.2ISSUE B PAGE 9 OF 14 FIGURE 5–STANDARD MECHANICAL SEALFIGURE 6ASSEMBLY Standard Mechanical Seal (Synthetic Rubber Bellows Type